Gaugwise YNXC100ZT 100mm Electric Contact Panel Mount Pressure Gauge — Bayonet Bezel, 380V AC
Gaugwise YNXC100ZT 100mm Electric Contact Panel Mount Pressure Gauge — Bayonet Bezel, 380V AC
SKU:GW-YNXC100ZT-0-0-0.1MPa
Couldn't load pickup availability
Share
A gauge and a pressure switch in one instrument — one panel cut-out instead of a gauge plus a separate switch. Free custom dial printing: add your logo, brand name or custom scale at no extra cost.
Specifications
| Dial | 100mm (4") |
| Accuracy | ±1.6% F.S. |
| Case | Stainless steel |
| Bezel | Bayonet (clamp-on) ring with three front mounting holes |
| Mounting | Panel cut-out from the front, no separate bracket required |
| Process connection | Axial centre-back, threaded M20x1.5 / G1/2 / 1/2NPT (configurable) |
| Contact rating | 380V AC, 30VA, adjustable upper and lower limit set points |
| Ranges | 0-0.1 / 0-0.6 / 0-1.6 / 0-2.5 / 0-6 MPa |
| Origin / HS | China / 9026.20 |
Where it fits
Control cabinet and switchgear door panels, alarm and interlock circuits, pump start-stop control, compressor and hydraulic power packs, boiler and chiller safety cut-outs, and any skid where the operator reads the pressure and the panel has to trip at a set point.
The bayonet bezel releases from the front, so an electrician can reach the terminals and the pointer can be zeroed without pulling the gauge off the panel — which matters when the instrument is wired into a live interlock loop.
Why buy from Gaugwise
Factory-direct, made to order in roughly 10 working days. Contacts are adjustable on site with a standard screwdriver, and set points can be pre-set at the factory if you send the trip values. Tell us your range, contact function (normally open or closed) and panel thickness, and we will confirm the build before production.
Frequently asked
What do the contacts actually switch?
A relay coil, a PLC digital input, an alarm lamp or a small solenoid — anything within the contact rating of 380V AC, 30VA. They are not designed to switch a pump motor directly.
Can the set points be adjusted on site?
Yes, with a standard screwdriver through the front after removing the bezel. Set points can also be pre-set at the factory if you send the trip values with the order.
Normally open or normally closed?
Specify at order. Most alarm circuits use normally closed so a broken wire also trips the alarm; most start circuits use normally open.
One contact or two?
This model carries upper and lower limit contacts. Single-contact versions exist for high-only or low-only duty.
Related reading
Electric contact gauges: set points, alarm and control — wiring logic for boiler and pump duty.
Panel-mount gauges: back flange vs bayonet bezel — mounting and cut-out practice.
YNXC100 — the radial-connection version of the same contact movement.