{"product_id":"gaugwise-ynxc100zt-100mm-electric-contact-panel-mount-pressure-gauge","title":"Gaugwise YNXC100ZT 100mm Electric Contact Panel Mount Pressure Gauge — Bayonet Bezel, 380V AC","description":"\u003cp\u003e\u003cstrong\u003eA gauge and a pressure switch in one instrument — one panel cut-out instead of a gauge plus a separate switch.\u003c\/strong\u003e Free custom dial printing: add your logo, brand name or custom scale at no extra cost.\u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDial\u003c\/td\u003e\n\u003ctd\u003e100mm (4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±1.6% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003eStainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBezel\u003c\/td\u003e\n\u003ctd\u003eBayonet (clamp-on) ring with three front mounting holes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003ePanel cut-out from the front, no separate bracket required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcess connection\u003c\/td\u003e\n\u003ctd\u003eAxial centre-back, threaded M20x1.5 \/ G1\/2 \/ 1\/2NPT (configurable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact rating\u003c\/td\u003e\n\u003ctd\u003e380V AC, 30VA, adjustable upper and lower limit set points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRanges\u003c\/td\u003e\n\u003ctd\u003e0-0.1 \/ 0-0.6 \/ 0-1.6 \/ 0-2.5 \/ 0-6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin \/ HS\u003c\/td\u003e\n\u003ctd\u003eChina \/ 9026.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhere it fits\u003c\/h2\u003e\n\u003cp\u003eControl cabinet and switchgear door panels, alarm and interlock circuits, pump start-stop control, compressor and hydraulic power packs, boiler and chiller safety cut-outs, and any skid where the operator reads the pressure and the panel has to trip at a set point.\u003c\/p\u003e\n\u003cp\u003eThe bayonet bezel releases from the front, so an electrician can reach the terminals and the pointer can be zeroed without pulling the gauge off the panel — which matters when the instrument is wired into a live interlock loop.\u003c\/p\u003e\n\u003ch2\u003eWhy buy from Gaugwise\u003c\/h2\u003e\n\u003cp\u003eFactory-direct, made to order in roughly 10 working days. Contacts are adjustable on site with a standard screwdriver, and set points can be pre-set at the factory if you send the trip values. Tell us your range, contact function (normally open or closed) and panel thickness, and we will confirm the build before production.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked\u003c\/h2\u003e\n\u003ch3\u003eWhat do the contacts actually switch?\u003c\/h3\u003e\n\u003cp\u003eA relay coil, a PLC digital input, an alarm lamp or a small solenoid — anything within the contact rating of 380V AC, 30VA. They are not designed to switch a pump motor directly.\u003c\/p\u003e\n\u003ch3\u003eCan the set points be adjusted on site?\u003c\/h3\u003e\n\u003cp\u003eYes, with a standard screwdriver through the front after removing the bezel. Set points can also be pre-set at the factory if you send the trip values with the order.\u003c\/p\u003e\n\u003ch3\u003eNormally open or normally closed?\u003c\/h3\u003e\n\u003cp\u003eSpecify at order. Most alarm circuits use normally closed so a broken wire also trips the alarm; most start circuits use normally open.\u003c\/p\u003e\n\u003ch3\u003eOne contact or two?\u003c\/h3\u003e\n\u003cp\u003eThis model carries upper and lower limit contacts. Single-contact versions exist for high-only or low-only duty.\u003c\/p\u003e\n\u003ch2\u003eRelated reading\u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.gaugwise.com\/blogs\/guides\/electric-contact-pressure-gauge-set-points-alarm-control-boilers-pumps\"\u003eElectric contact gauges: set points, alarm and control\u003c\/a\u003e — wiring logic for boiler and pump duty.\u003cbr\u003e\n\u003ca href=\"https:\/\/www.gaugwise.com\/blogs\/guides\/panel-mount-pressure-gauge-installation-back-flange-bayonet-ring\"\u003ePanel-mount gauges: back flange vs bayonet bezel\u003c\/a\u003e — mounting and cut-out practice.\u003cbr\u003e\n\u003ca href=\"https:\/\/www.gaugwise.com\/products\/gaugwise-ynxc100-100mm-electric-contact-pressure-gauge\"\u003eYNXC100\u003c\/a\u003e — the radial-connection version of the same contact movement.\u003c\/p\u003e\n","brand":"Gaugwise","offers":[{"title":"0-0.1MPa","offer_id":68024750964927,"sku":"GW-YNXC100ZT-0-0-0.1MPa","price":48.0,"currency_code":"USD","in_stock":true},{"title":"0-0.6MPa","offer_id":68024750997695,"sku":"GW-YNXC100ZT-0-0-0.6MPa","price":48.0,"currency_code":"USD","in_stock":true},{"title":"0-1.6MPa","offer_id":68024751030463,"sku":"GW-YNXC100ZT-0-0-1.6MPa","price":48.0,"currency_code":"USD","in_stock":true},{"title":"0-2.5MPa","offer_id":68024751063231,"sku":"GW-YNXC100ZT-0-0-2.5MPa","price":48.0,"currency_code":"USD","in_stock":true},{"title":"0-6MPa","offer_id":68024751095999,"sku":"GW-YNXC100ZT-0-0-6MPa","price":48.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0789\/2343\/2127\/files\/gaugwise-ynxc100zt-100mm-electric-contact-gauge-front-dial-bar-panel-mount.jpg?v=1795056736","url":"https:\/\/www.gaugwise.com\/products\/gaugwise-ynxc100zt-100mm-electric-contact-panel-mount-pressure-gauge","provider":"Gaugwise","version":"1.0","type":"link"}